Eppendorf SE 

Centrifuges 5702 / 5702 R (General Lab),with rotor A-4-38 and adapter for conical tubes

These low-speed, universally applicable centrifuges are especially suited for low to medium sample throughput in cell culture applications.

  • Extremely compact with small footprint
  • Maintenance-free motor
  • Dial controls and digital display
  • Powered lid locking
  • Short braking time
  • Automatic lid opening (model 5702 only
  • Rotor bowl made of stainless steel
  • Optimized: backwards adjusted air flow for sample cooling
  • The max. speed is depending on the installed rotor.


Additional features 5702 R:
  • Two programme keys for saving the parameters of two standard centrifugation processes
  • Adjustable acceleration rate and braking
  • Temperature setting from -9 °C to 40 °C
  • Stand-by cooling
  • Fast-temp-function
Centrifuges with rotor A-4-38 and adapter for conical tubes,15/50 ml

This centrifuges are General Lab Products for research purposes.
Speed:100 ... 4,400 1/min
For vessels:15/50 ml Tubes
Power supply:230 V, 50/60 Hz
Centrifuges 5702 / 5702 R (General Lab),with rotor A-4-38 and adapter for conical tubes


Centrifuges 5702 / 5702 R (General Lab),with rotor A-4-38 and adapter for conical tubes
X

Item added to basket.

Centrifuges 5702 / 5702 R (General Lab),with rotor A-4-38 and adapter for conical tubes

Customers also bought:

TypeMax. rcf
x·g
With coolingTemperatureDimensions (WxDxH)Weight
kg
Rated capacity
W
Plug typePKCat. No.in StockManuf. Prod. No. 
57023000No40 °C320 x 400 x 240 mm20200EU146606235702000320
5702 R3000Yes-9 ... 40 °C380 x 580 x 260 mm36380EU146606295703000425
57023000No40 °C320 x 400 x 240 mm20200UK146606245702000365 
5702 R3000Yes-9 ... 40 °C380 x 580 x 260 mm36380UK146606305703000460 
Accessories:
Fixed angle rotor F-45-24-11 for centrifuges 5702/5702 R/5702 RH / Eppendorf SE
Swing-out rotor A-4-38 for centrifuges 5702/5702 R/5702 RH, without buckets / Eppendorf SE
Swing-out rotor for centrifuges 5702/5702 R/5702 RH, incl. 4 round buckets à 85 ml / Eppendorf SE
Swing-out rotor A-8-17 for centrifuges 5702/5702 R/5702 RH, without adapters and rubber mats / Eppendorf SE
Fixed angle rotor with 30 steel sleeves F-35-30-17 for centrifuges 5702/5702 R/5702 RH, incl. 20 adapters for conical tubes and
Fixed angle rotor with 10 steel sleeves F-35-30-17 for centrifuges 5702/5702 R/5702 RH, incl. 10 adapters for conical tubes and
Fixed angle rotor F-45-18-17-Cryo for centrifuges 5702/5702 R/5702 RH / Eppendorf SE
Alternate products:
Centrifuges 5702 / 5702 R (IVD), without rotor / Eppendorf SE
Centrifuges 5702 R (IVD),with rotor A-4-38 and adapter for blood collection tubes / Eppendorf SE
Centrifuges 5702 RH (IVD), without rotor / Eppendorf SE