| Type OX-04G | For Oxygen | Description Alkaline batteries, operation time approx. 9000 h | Measuring 0 ... 25 %range | Resolution 0.1 % | Temp.
range -20 ... 50°C | Cat. No. 6.317 139 |
| Type OX-04 | For Oxygen | Description Alkaline batteries, operation time approx. 3000 h | Measuring 0 ... 25 %range | Resolution 0.1 % | Temp.
range -40 ... 60°C | Cat. No. 6.317 137 |
| Type OX-04 | For Oxygen | Description Ni-MH batteries, operation time approx. 2000 h | Measuring 0 ... 25 %range | Resolution 0.1 % | Temp.
range -40 ... 60°C | Cat. No. 6.317 138 |
| Type HS-04 | For Hydrogen sulfide | Description Alkaline batteries, operation time approx. 9000 h | Measuring 0 ... 30 ppmrange | Resolution 1 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 145 |
| Type HS-04 | For Hydrogen sulfide | Description Ni-MH batteries, operation time approx. 6000 h | Measuring 0 ... 30 ppmrange | Resolution 1 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 146 |
| Type CO-04 | For Carbon monoxide | Description Alkaline batteries, operation time approx. 9000 h | Measuring 0 ... 500 ppmrange | Resolution 10 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 141 |
| Type CO-04 | For Carbon monoxide | Description Ni-MH batteries, operation time approx. 6000 h | Measuring 0 ... 500 ppmrange | Resolution 10 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 142 |
| Type CO-04 (C-) | For Carbon monoxide -H2 | Description Alkaline batteries, operation time approx. 6200 h | Measuring 0 ... 500 ppmrange | Resolution 10 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 143 |
| Type CO-04 (C-) | For Carbon monoxide -H2 | Description Ni-MH batteries, operation time approx. 4200 h | Measuring 0 ... 500 ppmrange | Resolution 10 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 144 |
| Type CX-04 | For Carbon monoxide + Oxygen | Description Alkaline batteries, operation time approx. 4600 h | Measuring CO: 0 ... 500 ppm/ O2: 0 ... 25 %range | Resolution CO: 10 ppm/ O2: 0.1 % | Temp.
range -40 ... 60°C | Cat. No. 6.317 147 |
| Type CX-04 | For Carbon monoxide + Oxygen | Description Ni-MH batteries, operation time approx. 3000 h | Measuring CO: 0 ... 500 ppm/ O2: 0 ... 25 %range | Resolution CO: 10 ppm/ O2: 0.1 % | Temp.
range -40 ... 60°C | Cat. No. 6.317 148 |
| Type SC-04 | For Sulfur dioxide | Description Alkaline batteries, operation time approx. 3000 h | Measuring 0 ... 20 ppmrange | Resolution 0.05 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 149 |
| Type SC-04 | For Sulfur dioxide | Description Ni-MH batteries, operation time approx. 2000 h | Measuring 0 ... 20 ppmrange | Resolution 0.05 ppm | Temp.
range -40 ... 60°C | Cat. No. 6.317 150 |