Kern & Sohn 

Refractometer scales ORL-S

The refractometers can be optionally configured with individual scales according to your requirements.
In addition to the Brix and refractive index scales already pre-installed on the refractometer, a maximum of eight additional scales can be selected per device.
The free OXR-Basic software for performing measurements and exporting measurement results is available in the download area of the manufacturer's website.

This article cannot be purchased separately, as it is only available directly from the factory.
For:ORL 94BS
Refractometer scales ORL-S


Refractometer scales ORL-S
X

Item added to basket.

Refractometer scales ORL-S

Customers also bought:

TypeDescriptionPKCat. No.in StockManuf. Prod. No. 
ORL-S100AdBlue®/measuring range: 0,0 % - 51,0 %/division: 0,1 %14719797ORL-S100
ORL-S101Baumé/measuring range: 33,0 °Bé - 48,0 °Bé/division: 0,1 °Bé14719798ORL-S101
ORL-S102BF/measuring range: 1,000 kg/l - 1,500 kg/l/division: 0,001 kg/l14719799ORL-S102
ORL-S103Chlorine content seawater/measuring range: 0 ‰ - 57 ‰/division: 1 ‰14719800ORL-S103
ORL-S104Dextran/measuring range: 0,0 % - 10,6 %/division: 0,1 %14719801ORL-S104
ORL-S105EG (%)/measuring range: 0,0 % - 100,0 %/division: 0,1 %14719802ORL-S105
ORL-S106EG/measuring range: -50,0 °C - 0,0 °C/division: 0,1 °C14719803ORL-S106
ORL-S107Fructose (fruit sugar)/measuring range: 0,0 % - 68,9 %/division: 0,1 %14719804ORL-S107
ORL-S108Glucose (dextrose)/measuring range: 0,0 % - 59,9 %/division: 0,1 %14719805ORL-S108
ORL-S109Coffee TDS 1/measuring range: 0,0 - 25,0/division: 0,114719806ORL-S109
ORL-S110Coffee TDS 2/measuring range: 0,00 - 25,00/division: 0,0114719807ORL-S110
ORL-S111KMW (Babo)/measuring range: 0,0 °KMW - 25,0 °KMW/division: 0,1 °KMW14719808ORL-S111
ORL-S112Lactose (milk sugar)/measuring range: 0,0 % - 16,5 %/division: 0,1 %14719809ORL-S112
ORL-S113Maltose (malt sugar)/measuring range: 0,0 % - 15,6 %/division: 0,1 %14719810ORL-S113
ORL-S114Masspercentage/measuring range: 0 % (w/w) - 72 % (w/w)/division: 1 % (w/w)14719811ORL-S114
ORL-S115Oechsle/measuring range: 0,0 °Oe - 150,0 °Oe/division: 1 °Oe14719812ORL-S115
ORL-S116Oechsle/measuring range: 0,0 °Oe - 230,0 °Oe/division: 1 °Oe14719813ORL-S116
ORL-S117Plato/measuring range: 0,0 °P - 30,5 °P/division: 0,1 °P14719814ORL-S117
ORL-S118PG (%)/measuring range: 0,0 % - 100,0 %/division: 0,1 %14719815ORL-S118
ORL-S119PG/measuring range: -60,0 °C - 0,0 °C/division: 0,1 °C14719816ORL-S119
ORL-S120Salt (NaCl)/measuring range: 0,0 % - 28,0 %/division: 0,1 %14719817ORL-S120
ORL-S121Salt (NaCl) ‰/measuring range: 0 ‰ - 280 ‰/division: 1 ‰14719818ORL-S121
ORL-S122Salt content (sea water)/measuring range: 0 ‰ - 100 ‰/division: 1 ‰14719819ORL-S122
ORL-S123Serum proteine/measuring range: 0,0 g/dl - 12,0 g/dl/division: 0,1 g/dl14719820ORL-S123
ORL-S124Spec. gravity of original wort/measuring range: 1,000 SG Wort - 1,130 SG Wort/division: 0,001 SG Wort14719821ORL-S124
ORL-S125Spec. gravity/measuring range: 1,000 sg - 1,220 sg/division: 0,001 sg14719822ORL-S125
ORL-S126Spec. gravity/measuring range: 1,000 sg - 1,070 sg/division: 0,001 sg14719823ORL-S126
ORL-S127Urine (spec. gravity) - dog/measuring range: 1,000 sgU - 1,060 sgU/division: 0,001 sgU14719824ORL-S127
ORL-S128Urine (spec. gravity) - cat/measuring range: 1,000 sgU - 1,060 sgU/division: 0,001 sgU14719825ORL-S128
ORL-S129Urine (spec. gravity)/measuring range: 1,000 sgU - 1,050 sgU/division: 0,001 sgU14719826ORL-S129
ORL-S130Volume percent/measuring range: 0,0 % (v/v) - 22,0 % (v/v)/division: 0,1 %(v/v)14719827ORL-S130
ORL-S131Volume percent/measuring range: 0 % (v/v) - 80 % (v/v)/division: 1 % (v/v)14719828ORL-S131
ORL-S132Water content/measuring range: 5,0 % - 38,0 %/division: 0,1 %14719829ORL-S132
ORL-S133CW/measuring range: -60,0 °C - 0,0 °C/division: 0,1 °C14719830ORL-S133
Suitable for:
Digital refractometer ORL 94BS / Kern & Sohn